Texecom Premier 816 (WebWayOne Edition)

      SPT Wiring and WebWay Texecom Cable


A special version of the 816 known as the “Premier 816 WWO” is shipped with special software which allows it to communicate with the 2424 SPT, however it does not have a dialer which means that it can only be used with the 2424 system. 

Note that a cable assembly is required , which WebWayOne can supply although any 5-Way Molex type connecter can be modified.

The Texecom main board assembly has only 1 Com port on the PCB with a 5-pin connection interface.  This connects to the  TTL R, T and gnd terminals of the WebWayOne 2424 panel interface. 
This means that a local PC and the 2424 SPT cannot be connected to the panel at the same time. When connecting the local PC, leave the SPT disconnected for about 30 seconds before connecting to the PC. 
This should ensure that the panel recognizes that the SPT has been disconnected.
If there are problems establishing communications with the local PC, try entering user code + menu + 7 on the panel keypad (abort all communications).
 
The connection details are as follows:

Connect the WebWay PWR + and - to any relevant Power (+12V/+24V) and Ground (0V) terminals. Then the Texecom cable as follows;


WebWay SPT

Texecom

T - Red

Com Port 1

R - Green

RTN - Blue



Panel Configuration

Enter Programming Options

Menu 70: Communicator Options 

1: Enable Communicator ENABLED
2: Enable DTMF Dialing DISABLED
3: Pulse after 3rd attempt DISABLED
4: European Pulse Dialing DISABLED
5: Enable Test Transmission OPTIONAL
6: Enable Cancel Call Waiting DISABLED
7: Enable Backup to ARC DISABLED
8: Enable Blind Dialing DISABLED 

Menu 71: ARC 1 Menu

0: Phone number  Leave blank
1: Account number  Site Chip Number
2: Protocol SIA Level 2/3
3: Dial Attempts 9
4: Partition Options 1234 (optional)
5: Reporting Options 12345678 (optional)
8: Protocol Options * * * * * * * 8 – Connect Via IP

Menu 76: Download Menu

1: Com1 equipment type 003  - ComIP Module

2: Com IP-address & port 12700000000150561

Enter full octet (***.***.***.***) with no periods. Port should always be 50561
Example, IP 192.168.0.101 Port 50561: Enter as 19216800010150561
Note that 127.0.0.1 is interpreted by the SPT as ’use DHCP’.

3: LAN gateway IP (the local router) 127000000001

Enter full octet (***.***.***.***) with no periods. 
Example, IP 192.168.0.1: enter as 192168000001
Note that 127.0.0.1 is interpreted by the SPT as ’use DHCP’.

4: Netmask 8 (255.255.255.0)

This is selected from a list (see the Premier manual for full details).
DHCP settings for IP & LAN gateway will override this setting.

5: IP & port for main MCT

Enter full octet (***.***.***.***) with no periods. Port should always be 50561. 
Example, IP 85.200.242.12 Port 50561: Enter as 08520024201250561

Configuration can also be done via the Wintex program


Texecom Premier 816 (Standard Edition) 832, 412

The following models are integrated via a modem capture module, provided by WebWay. This type of integration does not support Upload/Download functionality.


The modem capture board needs wiring as follows to the Texecom panel.

WebWay Modem Capture

Texecom

A

T

B

R


Panel configuration

Enter Programming Options

Menu 70: Communicator Options 

1: Enable Communicator ENABLED
2: Enable DTMF Dialing ENABLED
3: Pulse after 3rd attempt   DISABLED
4: European Pulse Dialing DISABLED
5: Enable Test Transmission OPTIONAL
6: Enable Cancel Call Waiting DISABLED
7: Enable Backup to ARC DISABLED
8: Enable Blind Dialing ENABLED 

Menu 71: ARC 1 Menu

1: Phone number 01234 567890
2: Account number Partiton 1 Site Chip Number 
(Ensure reporting for partition(s) is enabled)

3: Protocol SIA Level 2/3
4: Dial Attempts 9
5: Partition Options 1234 (optional)
6: Reporting Options 12345678 (optional)
7: Protocol Options   All blank 

Panel configuration can also be completed with Texecoms wintex program.

In the comms menu set the following in Options;



In the comms menu set the following in ARCs;