Click here for Remote Manager and Upload / Download settings 

Click here to download the Menvier TS Guide - 

Menvier TS Series Menvier TS Series (373 KB)

Integration is complete for the following Panel(s)

TS690
TS790
TS900
TS2200
TS2500

A Menvier cable ( 05-0241) is required for the serial TTL connection.

Connect the WebWay panel interface R, T and RTN using the supplied molex cable. This goes T- red R-Green RTN-Blue and it plugs onto the 8 way Molex type connector labelled ‘Digi-Modem’. This is where the DC58 module would normally be plugged in.

Connect the WebWay PWR + and - to any relevant Power and Ground terminals.


TS 690 panel Configuration:

Engineer menu 2-C – Modem options

1. Callback No 1 -  123456

2. Callback No 2 -  No setting

3.Callback No 3  -  No setting

4. Password –
This must match the password configured in the Downloader application account setup

5. Modem site No –

This must match the site ID configured in the Downloader application account setup

6. Digi Programming

Telephone No 1  No setting

Telephone No 2  No setting

Account No 1         No setting

Account No 2         No setting

Reports 1          No setting

Reports 2          No setting

Set/Day                  No setting

Restore                 No setting

7. Digi Idle             No setting

TS 790/900/2200/2500 panel Configuration:

Engineer menu 3-C – Modem options

1. Callback No 1 123456

2. Callback No 2 No setting

3. Callback No 3 No setting

4. Password-
This must match the password configured in the Downloader application account setup

5.  Modem site No-
This must match the site ID configured in the Downloader application account setup

6. Digi Programming-

Telephone No 1 <01234 567890> - any number not 123456
Telephone No 2 No setting required
Telephone No 3 No setting required
Account No 1              <account number>
Account No 2 No setting required
Account No 3 No setting required
Reports to No 1 Set all reports on
Reports to No 2 Set all reports on
Reports to No 3 Set all reports on
Set/Day               Set all reports on
Restore           Set all reports on
Invert                 Set all reports on
Dialling mode Consecutive
Test call period Disabled
Digi output 1 is Line fault
Digi output 2 is Line fault
Extended format Full report
TOS calls are Disabled
Ring count is Instant

Press ‘0’ to protect numbers – Do not select


General troubleshooting tips for TS panels

When on menu 1 press ENTER to get to menu 2.
Press A to remove any additional digits if accidently entered.