Risco Gardtec GT600

Requirements

WebWayOne Modem Capture Module
SPT Firmware V3.47 or greater.
Remote Manager V3.2.2.4 or greater

WebWayOne Guide -  

Risco Gardtec Risco Gardtec (458 KB)


SPT Fitting

The WebWay SPT will not fit in the panel enclosure, please contact us for alternative enclosure solutions.



Connect the WebWay PWR + and - to any relevant Power (+12V/+24V) and Ground (0V) terminals and a modem capture connection as follows,

WebWay Modem Cpature

 Gardtec

A

A5 IN

B

B2 IN

RTN

RTN



Note – Use the two connections as shown above. There are some additional connectors to the right labelled in a similar fashion as A5 and B2, which should not be used.

Panel Programming

Digicom SIA and Triggers: 

1. Press [1][2][3][4][YES] to get into Engineer mode (If prompted also enter the authorise code)
2. If prompted ‘Do you want to use engineer mode - enter [Yes]
3. Press [3][4][YES] to jump to Digicom 
4. Press [NO] until you see ‘Mod + SIA’ 
5. Press [YES] 
6. Press [0] 
7. Press [NO] until you see ‘Channels’ 
8. Press [YES][YES] (To change channels/triggers) 
9. Press [NO] once 
10. Press [YES] until the “>” appears next to PA 
11. Press [NO] to change the ‘Off’ to ‘On’ 
12. Press [YES][YES] 
13. Press [0] repeatedly to get out of Engineer mode

 Digicom switching ON and Entering phone number: 

1. Press [1][2][3][4][YES] to get into Engineer mode 
2. Press [3][4][YES] to jump to Digicom 
3. Press [0] (go back) 
4. Press [NO] until you see ‘Functions’ 
5. Press [YES] 
6. Press [NO] until you see ‘Comms Functions’ 
7. Press [YES] 
8. Press [NO] until you see ‘Comms=On’ 
9. Press [YES] 
10. Press [NO] and key in the required Site Code/Id 
11. Press [YES] 
12. Press [NO] and key in the required ARC telephone number 
13. Press [YES] 
14. Press [0] repeatedly to get out of Engineer mode 

Set Line Monitor to low security: 

1. Press [1][2][3][4][YES] to get in to engineer mode. 
2. Press [3][4][YES] to jump to Digicom 
3. Press [0] (go back one menu place) 
4. Press [NO] till you see 'Functions' 
5. Press [YES] 
6. Press [NO] till you see 'Comms Functions' 
7. Press [YES] 
8. Press [YES] till you see 'Line Monitor' 
9. Press [NO] till you see 'Line Volts' 
10. Press [YES] 
11. Press [[NO] till you see 'Line Security' 
12. Press [NO] until ‘Low’ 
13. Press [YES] 
14. Press [0] multiple times to get out of engineer mode 

Set modem for UDL connectivity: 

1. Press [1][2][3][4][YES] to get in to engineer mode. 
2. Press [3][4][YES] to jump to Digicom
3. Press [0] (go back one menu place) 
4. Press [NO] till you see 'Functions' 
5. Press [YES] 
6. Press [NO] till you see 'Program Modem Functions' 
7. Press [YES] 
8. Press [NO] till you see ‘Modem Mode’ 
9. Press [NO] till ‘No Return’ is selected. 
10. Press [YES]. 
11. Next you will see ‘Double Ring’ 
12. Press [NO] until ‘Off’ is selected. 
13. Press [YES] until ‘Site ID code’ 
14. Press [NO] and insert Site\account number 
15. Press [YES] and you will see ‘Password’ 
16. Press [NO] and insert password 
17. Press [YES] and you will see ‘Phone number 1’ 
18. Press [NO] and insert any telephone number 
19. Press [YES] until you see ‘Modem Access’ 
20. Press [NO] until ‘Any Time’ is selected 
21. Press [YES] 
22. Press [0] multiple times to get out of engineer mode