Serial Connectivity MAXSYS PC4020 Configuration


Maxsys Range User Manual -  

DSC User Manual Maxsys DSC User Manual Maxsys (1830 KB)

Click here for Remote Manager and Upload / Download settings 

Serial Connection

The WebWay is designed to emulate the DSC T-Link module. WebWayOne Cable (TBC) will be needed for integration or a cable is adapted to suit as follows,

WebWay SPT

DSC

232 T

Pin 1

RTN

Pin 2

RTN

Pin 3

232 R

Pin 4


         WebWayOne SPT Connections

Connect the WebWay PWR + and - to any relevant Power (+12V/+24V) and Ground (0V) terminals



DSC Maxsys 4020

Panel Programming

Engineer login and set-up:

1. Press *8 
2. Keypad displays ‘Enter Your Installer Code’   >  Press 5555  
3. Scroll to (00) System Area and press * 
4. Scroll to (03) DLS Section and press * 
5. Scroll to (00) DLS Toggles and press * 
6. Set DLS Enabled = Y   >  Press # twice
7. Scroll to (04) Communicator and press * 
8. Scroll to (00) Main Items and press * 
9. Scroll to (00) 1st Number and press * 
10. Scroll to (00) Pgm Tel Number and press * 
11. Set to CAAA and remove ‘D’ from the beginning 
12. Scroll to (01) Comms Format and press *   >  Set to SIA Fsk Format
13. Scroll to (02) Dialer Direction and press *  
14. Toggle events to be sent   >  Press # twice.
15. Scroll to (03) System Account and press * 
16. Set Account Code, normally same Site ID as SPT 
17. Press # until you are back to step 9
18. Scroll to (01) Communications options and press * 
19. Set Communicator Enabled = Y 
20. Set TLM Enabled = N 
21. Set Automatic SIA codes = Y 
22. Set TLink Enabled = Y