The following DSC panels are supported:

PC1616
PC1832
PC1864

DSC PC Range User Manual - 

DSC User Manual DSC User Manual (3007 KB)

Click here for Remote Manager and Upload / Download settings 


 SPT Connection

Modem Capture Connectivity PC1616 / PC1832 / PC1864 Configuration

Connect the WebWay PSTN panel interface A and to the A and B terminals of the DSC control panel. Connect the WebWay PWR + and - to the Aux + and Aux - of the DSC control panel.
Connect the WebWay PWR + and - to any relevant Power (+12V/+24V) and Ground (0V) terminals.

 *8  Then enter installers code

1. Go to section 301: Enter telephone number <01234 567890> (any valid phone number is acceptable)
2. Go to section 310: Enter account number 
3. Go to section 350: Enter communicator format to SIA <04>
4. Go to section 380: Ensure option 1 is enabled to <1________>
5. Go to section 381: Ensure options 5 & 6 are enabled - the rest clear <____56__>
6. Go to section 382: All must be clear <_________>
7. Go to section 401: Option 1 must be set - the rest clear<1________>
8. Go to section 403: Enter DLS access code <______>
9. Go to section 404: Enter DLS panel identification code <______>
10. Go to section 406: Set number of rings to <002>