The following panels have been integrated to the WebWay signalling solution

GE Aritech 
-CD95 
-CD72

WebWayOne Guide - 

CD95 Guide CD95 Guide (495 KB)

CD95 User Manual -

CD95 User Manual CD95 User Manual (2227 KB)

Click here for Remote Manager and Upload / Download settings 

Integration is via modem capture and requires a RD62 Dialler and the WebWay modem capture module is required (22-5059), this will emulate the PSTN network and deliver SIA alarming.

   SPT Connections   CD 95 Modem Connection

Panel Configuration

From the engineer menu enter the dialler menu in the normal way.

IMPORTANT  - The following settings should be applied after the dialler configuration has been defaulted.

Configuration for alarm transmission.


Tel/Account Nbrs- Centr. Station 1

CS1 Teleph. Nbr <any number 6 digits or more NOT 123456>

CS1 Account Nbrs

CS1Acc. Nbr. 1 <account no>
CS1Acc. Nbr. 2-8 No settings
Protocol CS1 X SIA
CS1: ALI No
Centr. Station 2 No settings
Centr. Station 3 No settings
Centr. Station 4 No settings

Upload / Download
See notes below regarding settings for connection to Transport PC (UDL)

Alternate/Nbrs No settings
Hide Nbrs No settings
PABX No.          No settings

Dial Options
Dialling DTMF
Dial tone type UK
Wait dial tone No
Call interval 60
Retry period 120
Calls for FTC 03

Report options
Configure as required by ARC for alarm reporting

Event delay(x5) 00

Protocol Opt
SIA 1
1 event/call Yes
1 acc/call No
2/3 Digit Event No. 3 Digit Event No.
SIA Freq Bell

Test call No settings
Engineer No settings

Line Monitor
Line monitor On
Off-hook options Ignore off-hook
Dont Ans ringing Dont ans ringing
D. Tone test Yes

Configuration for connection to Upload / Download

The CD series panels can only use secure callback for establishing a UDL connection. This means that it will answer the incoming call from the WebWay, verify it, drop the call and dial back out. The WebWay recognises the outgoing call as being different from an alarm signalling call because of the number dialled by the panel. 

The configuration for UDL operation is set the U/D section of the Dialler menu described in the previous section.

U/D
U/D Teleph.Nbr1 must be set to 123456
U/D Teleph.Nbr2 not required
U/D Acc. Nbr. set to the same account number as for alarms
U/D Freq CCITT

U/D Init
PC calls Yes
User code Yes
On line Yes

Previous menu
Dump Eng mem. No
U/D if armed Yes/No - selection depends on install requirement
Ans PC rings